
↓
↓↓
↓
Display is CD (CURRENT DAY OF THE WEEK). Press UP/DOWN buttons to adjust the
current day of the week. ONLY AVAILABLE IF DAY OF THE WEEK CONTROL IS
ON IN MASTER PROGRAAMING
Model 5600 SXT- Master Programming Chart
FROM SERVICE MODE:-
• To enter master programming mode, set the Time of Day display to 12:01 P.M.
↓
↓↓
↓
↓
↓↓
↓
Press and hold and buttons together until the programming icon
replaces the service icon
Display is DF (DISPLAY FORMAT) →
→→
→ Unit of measure for volume and display format for
time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings.
↓
↓↓
↓
↓
↓↓
↓
Display is VT (VALVE TYPE) →
→→
→ type of valve setting [Factory Setting: St1b (Standard
Downflow/Upflow, Single Backwash]. Press UP/DOWN buttons to adjust the settings.
↓
↓↓
↓
↓
↓↓
↓
Display is CT (Control Type)→
→→
→ type of regeneration [Factory Setting: Fd (Meter Delayed)].
Press UP/DOWN buttons to adjust the settings.
↓
↓↓
↓
↓
↓↓
↓
Display is NT (Number of Tanks)→
→→
→ [Factory Default Setting: 1]. Do not change the setting.
↓
↓↓
↓
↓
↓↓
↓
Display is UNIT CAPACITY →
→→
→ Capacity in grains for softeners and in ppm per gallon for iron
filters. [Factory Default Setting: Refer to User
Manual].
Extra Cycle
Extra Cycle
Extra Cycle
Extra Cycle
Extra Cycle
Comentarios a estos manuales