
7000 Master Programming Mode
Page 6
6. Regeneration Time (No display Code)
NOTE:
This program step is not available for Regeneration Type Meter Immediate [ 7 - - 2 ].
Use this program step to set the Time of Day a Regeneration occurs. A non-flashing colon between the hour
and minute digits identifies the Regeneration Time display.
Example:
—Use the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button to proceed to the next step.
NOTE:
When the piston type is Fltr, Regeneration time defaults to:
— 12:00 A.M., US
— 00:00, metric
7. Regeneration Day Override (Display code A)
Use this program step, identified by the letter A in the first digit, to set the maximum number of days the unit
can be In Service without a regeneration.
—For Regeneration Type Time Clock Delayed [ 7 - - 1 ], the system regenerates at the time set in program
step #5 after the number of days programmed in this step.
— For any Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ], the system regenerates after the number
of days programmed in this step at the Regeneration Time setting, step #6.
Example:
—Use the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button to proceed to the next step.
Range = 12:00 – 11:59 P.M., US
Range = 00:00 – 23:59, metric
2 o’clock A.M. regeneration time Setting: [ 2:00 ]
Default =
2:00 A.M.
Range = 0 – 199, Time Clock Delayed [ 7 - - 1 ]
Range = 1 – 199, Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ]
Default =
7 days, Time Clock Delayed [ 7 - - 1 ]
Default =
Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ]
Override every 7 days Setting: [ A -- 7 ]
Option turned off Setting: [ A OFF ]
Comentarios a estos manuales